#1.filter housing HH9020K12
operating pressure:max 350bar
adjustment of the bypass valve:delta p=3,4 bar +- 0,3bar
connection:manifold type (o-rings)
seals:nitrile
#2.Filter Element HC9020FKP4H
filter medium:ultipor III
filter value: beta 3>=200
minimum filter value guaranteed till a delta p=4 bar
length:4"
seal:nitrile
compression pressure fall:delta p=20 dbar (ISO 2941)
#3.Indicator RC861MZ090H
visual indicator
type D
settings:2,5bar
|